- H2S sulfuretted hydrogen
-
H2S gas sensor,Sulfuretted hydrogen gas sensor
Range |
Maximum Overload |
Resolution |
DATA |
Brand |
model |
0-30ppm |
30ppm |
<0.1ppm |
Output Signal:100nA/ppm±30nA/ppm;T90<30S;Expected Operating Life>18months;3-electrode electrochemical;Not required |
CITY |
H2S 3E 30 |
0-50ppm |
50ppm |
<0.25ppm |
Output Signal:0.37±0.07μA/ppm;T90<30S;Expected Operating Life>18months;3-electrode electrochemical;Not required |
SolidsenS |
7H2S-50 |
|
250ppm |
0.03ppm |
Output Signal:950-1400nA/ppm;T90<25S;Expected Operating Life>48months;3-electrode electrochemical;Not required |
alphasense |
H2S-AH (big current ) |
|
200ppm |
0.02ppm |
Output Signal:1500-2000nA/ppm;T90<30S;Expected Operating Life>48months;3-electrode electrochemical;Not required |
alphasense |
H2S-BH (7,big current ) |
|
500ppm |
0.1ppm |
Output Signal:1.70±0.30μA/ppm;T90<30S;Expected Operating Life>12months;3-electrode electrochemical;Not required |
CITY |
3HH |
|
|
|
Output Signal:1.70±0.30μA/ppm;T90<30S;Expected Operating Life>24months;3-electrode electrochemical;Not required |
CITY |
7HH |
|
|
|
Output Signal:1700±400nA/ppm;T90<40S;Expected Operating Life>24months;3-electrode electrochemical;Not required |
SGX |
7H2SHO |
0-100ppm |
100ppm |
<0.3ppm |
Output Signal:750nA/ppm±150nA/ ppm;T90<30S;Expected Operating Life>48months;3-electrode electrochemical;Not required |
CITY |
H2S 3E 100 |
|
500ppm |
<0.1ppm |
Output Signal:0.7±0.15μA/ppm;T90<20S;Expected Operating Life>24months;3-electrode electrochemical;Not required |
CITY |
4HS+ |
|
|
0.1ppm |
Output Signal:0.8±0.20μA/ppm;T90<30S;Expected Operating Life24months;3-electrode electrochemical;Not required |
SolidsenS |
4H2S-100 |
|
|
<0.1ppm |
Output Signal:700±250nA/ppm;T90<30S;Expected Operating Life>24months;3-electrode electrochemical;Not required |
SGX |
4H2S |
|
|
<0.1ppm |
Output Signal:1200±250nA/ppm;T90<30S;Expected Operating Life>24months;3-electrode electrochemical;Not required |
SGX |
4H2SHO |
|
|
0.05ppm |
Output Signal:550-875nA/ppm;T90<25S;Expected Operating Life>48months;3-electrode electrochemical;Not required |
alphasense |
H2S-A1 |
0-200ppm |
1000ppm |
0.25ppm |
Output Signal:0.37±0.07μA/ppm;T90<35S;Expected Operating Life>24months;3-electrode electrochemical;Not required |
CITY |
7H |
|
|
|
Output Signal:0.37±0.07μA/ppm;T90<30S;Expected Operating Life>24months;3-electrode electrochemical;Not required |
SolidsenS |
7H2S-200 |
|
|
<0.2ppm |
Output Signal:370±100nA/ppm;T90<40S;Expected Operating Life>24months;3-electrode electrochemical;Not required |
DD |
7H2S |
|
500ppm |
0.05ppm |
Output Signal:300-440nA/ppm;T90<35S;Expected Operating Life>48months;3-electrode electrochemical;Not required |
alphasense |
H2S-B1 |
0-1000ppm |
2000ppm |
1ppm |
Output Signal:0.09±0.04μA/ppm;T90<45;Expected Operating Life24months;3-electrode electrochemical;Not required |
SolidsenS |
4H2S-1000 |
0-2000ppm |
|
0.5ppm |
Output Signal:80-115nA/ppm;T90<35S;Expected Operating Life48months;3-electrode electrochemical;Not required |
alphasense |
H2S-BE |
0-5000ppm |
|
5ppm |
Output Signal:15±5nA/ppm;T90<35S;Expected Operating Life24months;3-electrode electrochemical;Not required |
Membrapor |
H2S/C-5000 |
5-100ppm |
|
|
Semiconductor,Ammonia leak detection in refrigerators Ventilation control for agricultural and poultry industries |
FIGARO |
TGS2444 |
- Pre:4CH3SH mercaptan
- Next:HCN hydrogen cyanide